lv    eng    rus

ab-1

ab-1

pr-1

ab-1

co-1

ab-1

Blupoint Security

Fiber Optic Data links

Satellite Network equipment and services

3G video surveillance camera

GPS/GSM Terminal

PRODUCTS IN DEVELOPMENT STAGE:

Personiser

Lattag System

Low consumption
efficient energy
control

Blupoint Security System

GSM / RF BLUPOINT control module
for protection of the property, control and process management.

Figure 1. fig-1

Universal module (Figure 1) is designed for integration in the security system, management and control. The module is suitable for use by personnel of security structures, as well as for immediately alerting the end user of the situation on his property.

You can easily control the universal programmable module inputs, the availability of power to the unit, the temperature of the device, the GSM signal, and also a warning signal is transmitted in the case of illegal opening of the housing unit.

The equipment is designed for placement in a residential area, as well as for use in industrial facilities: public utilities, boilers, etc. The equipment can be used in building automation systems (Smarthouse). The example (Figure 2) shows the use of universal module in metal housings of industrial devices.

Figure 2. met

Control is carried out from a mobile phone using SMS messages. A continuous system operation is controlled through the GPRS system, and it has the ability to connect to the console of the security company for 24h monitoring of the object and instant professional security call.

The equipment can simultaneously monitor different parameters of the connected loops: loop resistance, temperature settings, voltage in the electrical circuits controlled, and transmit detailed operational messages to mobile phone user.

Figure 3 shows a variant of the module location in an office housing.

Figure 3. f3

Up to 15 wireless modules for external protection and control can be connected to the GSM / RF module (Figure 4)

Figure 4. f4

Each external module controls: integrated magnetic sensor (Figure 5 shows the module with the magnet), built-in temperature sensor, outside zone to which you can connect any sensor (smoke, water or gas leaks, broken glass, a motion sensor, and tmp.), measurement of the battery voltage of external power module, illegal opening sensor.

Figure 5. f5

In automatic mode you can control the voltage of battery of the external devices. An alarm is sent from the radio module, and if the battery voltage drops to a critical value the sensors are triggered - either areas or temperature change is beyond the scope of the established thresholds.

Product specification of the GSM alarm system BLUPOINT:

The total number of protected areas in the system .............................................. 16
The number of protected zones of the basic module ............................................. 8
Relay output in Control module ............................................................................. yes
The threshold trigger loop: normal, open, short .................................................... yes
Range of temperature measurement in the standard PT1000 .......................... 60 ... +300 °C
Calibrated accuracy of the temperature reading ................................................ ± 2 °C
Measurement range of loop resistance ............................................................. 0 ... 32000 Ω
Calibrated accuracy of the resistance reading .................................................... ± 10 Ω
The measurement range of voltage loop .......................................................... 0 ... 32000 mV
Calibrated accuracy of the voltage readings ...................................................... ± 10 mV
Power supply of control module ......................................................................... 9 ... 32V
The battery life of management module without an external power supply ......... 24h
Number of stored phone numbers for messages ................................................... 5
Pre-set schedule of regular reports on the state of the system ............................. yes
Warning about the loss of voltage ......................................................................... yes
Signal for opening of the housing (triggering of tamper switch) ............................. yes
Possibility of GSM signal strength measurement (dB/m) ......................................... yes
Possibility of measuring the temperature of the device .......................................... yes
Setting the alarm threshold temperature PT1000 (upper and lower) ..................... yes
Storing event data in the non-volatile memory ....................................................... yes
Data transfer to a monitoring server of system, data control and storage ............. yes
Choice of language (Russian, Latvian, English or any other) .................................. yes
Dimensions of the basic module ........................................................................... 65 х 90 mm
Dimensions of the office performance housing ............................................. 100 х 130 х 30 mm

Wireless System:

Number of external radio modules ............................................................................ 15
Number of radio-controlled devices zones ................................................................. 7
Zones controlled by the radio module:
magnetic sensor ...................................................................................................... yes
temperature sensor ................................................................................................ yes
programmed external zone ..................................................................................... yes
control of battery voltage ........................................................................................ yes
tamper turn-off switch ............................................................................................. yes
radio module output for connection of the relay switch (500 mA) ........................... yes
Time of the offline operations of the external radio module
with battery model CR2450 3V .............................................................................. 1 year
Size of the wireless module housing ............................................................... 50 х 70 х 13 mm

Appliances for Smartphone:

Software for controlling devices for Smartphone or tablet computers (Android) ..... yes
Number of devices connected to one Smartphone ............................................ unlimited
An identification name and password for every object .......................................... yes
Full device configuration from the appliances for Smartphone .............................. yes
Report of events with dates and times ................................................................. yes
Option of scanning the status of the device .......................................................... yes
Scanning/changing the non-volatile storage of the device .................................... yes
Turn-on/Turn-off (connected to the device) switches ............................................ yes
Full device set-up/removal from the security ......................................................... yes
Revision of the device set-up/removal from the security of the object .................. yes
Connecting and managing of surveillance cameras ............................................... yes

Software (application) for Smartphone provides a convenient control over the system and receiving of information (examples in drawing 6)

Drawing 6 f62 f63 f64 g65 f66

One application for Smartphone allows to program an unlimited number of devices (objects), which means that there is a possibility of installing the devices in the system of collective security, and provides an opportunity for one user to control various objects.
 
In the screen caption ‘Events’ you can see time when the alarm has been set off and disabled.
In the screen caption ‘Configuration’ there is an option of setting languages, passwords, connecting phones, setting up zones of security and control, messages/signals, calibrations of sensors and other parameters.

In the screen caption ‘Control’ you can turn on/turn off devices and mechanisms connected to the system, which are connected to the base module or external wireless modules.             

In the screen of the security functions a connection or disconnection from the security is possible, depending on the programmed zones and regions. Also, in the event of alarm the zone and its parameters are displayed (rise of the temperature, triggering of the security sensors etc.)